- All news
- FCC withdraws SGS-CSTC Shenzhen lab over 15% state stake
FCC withdraws SGS-CSTC Shenzhen lab over 15% state stake
On 13 November 2026 the FCC's Office of Engineering and Technology (OET) withdrew its recognition of SGS-CSTC Standards Technical Services Co. Ltd. Shenzhen Branch (designation CN1336) as an accredited test laboratory. Order DA 26-1233, in ET Docket 26-111, took effect on release. The ground is ownership, not test quality: SGS Hong Kong, a subsidiary of the Swiss group SGS SA, holds 85% of the lab, but the remaining 15% belongs to a company under a Chinese government institution. Under 47 CFR 2.902, a stake of 10% or more held by a prohibited entity is enough, and OET held that the rule left it no choice.
In short:
- What: the FCC "will no longer recognize within its equipment authorization program test data or measurements that are performed after this date" by the lab (DA 26-1233, para. 19). The order was adopted and released on 13 November 2026.
- Why: China Standard Science and Technology Group Co., Ltd. (CSTC) holds 15% of the lab. The lab itself described CSTC as a "PRC incorporated SOE entity" under the China National Institute of Standardization (CNIS).
- The rule: § 2.951(d)(1) requires withdrawal for a lab "owned by, controlled by, or subject to the direction of a prohibited entity", and § 2.902 covers any entity in which another entity has "direct or indirect ownership or control of 10% or more equity, voting interest, or stock" (para. 18).
- What did not count: the 85% majority, the seven board seats out of ten and the General Manager appointed by SGS Hong Kong.
- New name: the lab told OET on 30 September 2026 that it is now called SGS Tongfang Technical Services (Suzhou) Co. Ltd. Shenzhen Branch, with no change in ownership.
A six-month procedure
Section titled “A six-month procedure”The order recounts the steps of the proceeding, which follow § 2.951(e): written notice of the intent to withdraw and at least 30 days to respond.
| Date | Step | Document |
|---|---|---|
| 2 April 2026 | In reply to an OET inquiry, the lab describes itself as a joint venture between SGS Hong Kong (85%) and CSTC (15%) | Exhibit 2 to DA 26-1233 |
| 11 May 2026 | Notice of intent to begin proceedings to withdraw recognition | DA 26-461 |
| 12 June 2026 | Lab's response to the notice | Exhibit 3 to DA 26-1233 |
| 20 July 2026 | Order instituting the withdrawal proceeding | DA 26-744 |
| 24 August 2026 | Lab's response to the order | Exhibit 4 to DA 26-1233 |
| 30 September 2026 | Lab reports its new name, with no change in ownership | Exhibit 1 to DA 26-1233 |
| 13 November 2026 | Recognition withdrawn, effective on release | DA 26-1233 |
In the notice of intent, quoted in the order (para. 9), OET noted that the lab's test reports described it as accredited by A2LA (certificate No. 3816.01), recognized by the FCC (CN1336) and recognized by ISED (CAB identifier CN0006). DA 26-1233 deals with FCC recognition only.
The lab's case, and why it failed
Section titled “The lab's case, and why it failed”The lab did not dispute the 15%. Its argument was about control (para. 5 to 8 and 12 to 17):
- SGS Hong Kong holds 85%, appoints seven of the ten directors and the General Manager, who runs daily management, technical supervision, staffing and laboratory oversight.
- CSTC appoints three directors, the Chairman of the Board and a Deputy General Manager, whom the lab described as having "only a subordinate and supporting role". According to the lab, the Chairman has no operational or technical authority and no access to the laboratory facilities, the FCC-related IT systems, the test data or the test reports.
- Ordinary decisions pass by simple majority. Major corporate actions, such as amendments to the articles, capital changes, merger or dissolution, require unanimity.
- In the lab's reading, FCC precedent on de facto control calls for a case-by-case "totality of the circumstances" analysis, in which a minority stake alone is not decisive. The lab added that earlier withdrawals had involved 49% and 100% ownership by state-owned enterprises and institutions (note 29).
OET answered with the text of the rule (para. 18): "By the plain language" of § 2.951(d), as clarified by § 2.902, it "is required to withdraw recognition" because a prohibited entity has "direct or indirect ownership or control of 10% or more equity, voting interest, or stock". The People's Republic of China is a prohibited entity under § 2.902, which refers to the foreign adversaries designated by the Department of Commerce in 15 CFR 791.4 (para. 3). The order rests its conclusion on that threshold alone (para. 18 and 19).
What it means for equipment authorizations
Section titled “What it means for equipment authorizations”Under § 2.948(a), equipment authorized under the certification procedure must be tested in a laboratory that is accredited and recognized by the Commission under § 2.951. Measurements this lab performs after 13 November 2026 can no longer support an FCC application.
For equipment under the SDoC procedure, § 2.906(a)(1) separately provides that the testing "must not be performed at a measurement facility that is owned by, controlled by, or under the direction of a prohibited entity, as defined in § 2.902". That is the finding OET made about this lab.
The order speaks of data "performed after this date". It does not address equipment already certified on the lab's earlier reports, and lists no FCC IDs.
Ownership versus location
Section titled “Ownership versus location”This withdrawal rests on the ownership rules of the Equipment Authorization Integrity Report and Order in ET Docket 24-136, which the article on FCC 26-28 describes. It is a separate ground from the one adopted in FCC 26-73, which ends recognition of labs located in, or testing from, non-reciprocal economies on 1 December 2028, whoever owns them (FCC 26-73, para. 39, and § 2.951(b)(4) and (d)(4) in Appendix A). The ownership ground applies now, lab by lab, and a majority held by a group from outside the PRC does not offset a 10% stake held by a prohibited entity.
What to do
Section titled “What to do”- Check where your FCC test data comes from. Look for designation CN1336, and for both the old and the new name of the lab, in test reports for pending applications, planned filings, permissive changes and SDoC files.
- Move testing performed after 13 November 2026 to another recognized lab. Data the lab produces after that date will not be accepted in the equipment authorization program.
- Ask your test labs about their ownership. The test is any direct or indirect holding of 10% or more by a prohibited entity, regardless of who runs the lab day to day.
- For SDoC products, make sure the compliance testing was not carried out at a facility covered by § 2.906(a)(1), since under § 2.906(a)(2) no sample or test data goes to the FCC unless it asks for them.
Going further
Section titled “Going further”- FCC 26-28 and the Trusted Test Lab track: the ownership thresholds and the earlier lab withdrawals
- FCC 26-73 and non-reciprocal test labs: the location rule that applies from 1 December 2028
- FCC procedure: certification, SDoC and the role of the TCB
- Conformity assessment bodies and accreditation: who recognizes which test lab
Sources & references
- SGS-CSTC Standards Technical Services Co. Ltd. (Shenzhen), Order Withdrawing Recognition as an Accredited Test Laboratory, DA 26-1233, ET Docket 26-111 (13 November 2026), Federal Communications Commission docs.fcc.gov/public/attachments/DA-26-1233A1.pdf
- Order Instituting Proceeding to Withdraw Recognition as an Accredited Test Laboratory, DA 26-744, ET Docket 26-111 (20 July 2026), Federal Communications Commission docs.fcc.gov/public/attachments/DA-26-744A1.pdf
- Notice of Intent to Begin Proceedings to Withdraw Recognition as an Accredited Test Laboratory, DA 26-461, ET Docket 26-111 (11 May 2026), Federal Communications Commission docs.fcc.gov/public/attachments/DA-26-461A1.pdf
- FCC 26-73, Third Report and Order and Third Further Notice of Proposed Rulemaking, ET Docket 24-136 (released 30 October 2026), Federal Communications Commission docs.fcc.gov/public/attachments/FCC-26-73A1.pdf
- 47 CFR 2.951, Recognition of measurement facilities (eCFR), National Archives (eCFR) www.ecfr.gov/current/title-47/chapter-I/subchapter-A/part-2/subpart-J/section-2.951
- 47 CFR 2.906, Supplier's Declaration of Conformity (eCFR), National Archives (eCFR) www.ecfr.gov/current/title-47/chapter-I/subchapter-A/part-2/subpart-J/section-2.906